Background

The Tenafly Racquet Club is a year-round indoor facility with 8 tennis courts, located in Tenafly, New Jersey.

Original Situation

The Tenafly Racquet Club was looking to upgrade their existing lighting system as part of an overall building renovation. The objectives included increasing lighting levels, reducing energy consumption and maintenance costs, and gaining control capabilities, including on/off and dimming. The club also sought to decrease glare by changing its lighting method from direct (fluorescent) to indirect.

The existing lighting system consisted of 208 4 T12 100W fluorescent fixtures, and the club was considering upgrading to 1000W.

The Solution

Metrolight’s system integrator partner in the US, MicroStart LLC, deploys turnkey projects that include lighting system upgrades and new installations. MicroStart recommended replacing the club’s fluorescent fixtures with Metrolight Smart Electronic Ballast for HID™ 400W. In addition, MicroStart would install unique light suspensions that would enable indirect fixture installation with invisible wiring. Finally, Metrolight Control™ would be installed as a central control system, to allow lighting control per fixture and/or per court (group of 22).

The Result

After the Metrolight installation, the Tenafly Racquet Club was able to provide shadowless, non-glare lighting on its courts. In addition, the club gained energy savings of 35%, while nearly tripling light output and significantly reducing maintenance costs.

The comparison table below shows estimated costs for the 1000W option and the savings achieved by installing Metrolight Smart Electronic Ballast for HID™. It also shows the Return on Investment (ROI) compared to a fluorescent installation.
Features 1000W Magnetic Fluorescent Metrolight
Lamp Power Wattage / Setup1 1000 Watts 400 Watts 388 Watts
Power Consumption W 1111 471 408
Lumens Measured 836 Lumens 278 Lumens 836 Lumens
Operating Hours 15 15 15
Electricity Cost $ 0.12 0.12 0.12
Total Installation Cost2 $ $54,048 - $66,880
Total Annual Electricity Cost $ (US$) $70,073 $64,365 $47,227
Average Annual Maintenance Cost (US$) $1,500 $23,920 $6,600
Total Annual Savings $ -$5,708 - $34,458
ROI NOT FEASIBLE 1.94
Notes:
1. Power reduction due to dimming (15%) for 20% of the time
2. The calculations do not include Metrolight software cost for lighting control and monitoring, as well as the new mechanical/electrical infrastructure installation in the building